بلوک دیواری

بلوک سفالی ۲۰

KW-20

40 × 20 × 20 cm

بلوک بیست سانتی‌متری با ابعاد ۲۰×۲۰×۴۰، متداول‌ترین انتخاب برای دیوار میان‌قاب و دیوار خارجی ساختمان‌های اسکلت‌دار.

  • Thermal

    λ = 0.26

    Thermal insulation

  • Acoustic

    48 dB

    Sound insulation

  • Fire

    180 min

    Fire resistance

Specifications

Technical specifications for بلوک سفالی ۲۰
Property Value
Nominal dimensions 40 × 20 × 20 cm
Wall thickness 20 cm
Weight each 11.5 kg
Compressive strength 6.5 MPa
Thermal conductivity (λ) 0.26 W/m·K
Thermal resistance (R) 0.769 m²·K/W
Water absorption 13.8 %
Sound reduction 48 dB
Fire resistance 180 min
Void ratio 58 %
Units per m² 12.5 pcs
Units per pallet 96 pcs
Mortar used 21 litres/m²
  • استاندارد ملی ایران ۷
  • مبحث ۱۹ مقررات ملی ساختمان
  • مبحث ۲۱ — پدافند غیرعامل

Why this product?

بلوک بیست سانتی‌متری با ابعاد ۲۰×۲۰×۴۰، متداول‌ترین انتخاب برای دیوار میان‌قاب و دیوار خارجی ساختمان‌های اسکلت‌دار.

عایق حرارتی
68
عایق صوتی
80
مقاومت سازه‌ای
72

Features

  • یک بلوک معادل ۸ آجر — سرعت اجرای چند برابر
  • مقاومت فشاری ۶٫۵ مگاپاسکال
  • مقاومت آتش سه ساعته

Applications

  • دیوار خارجی ساختمان مسکونی
  • دیوار میان‌قاب اسکلت بتنی و فولادی
  • دیوار محوطه صنعتی

Installation

How it is laid

The five points that matter most to how the finished wall performs.

Full installation guide
  1. 1

    Level the bed

    The first course goes on a perfectly level mortar bed. Every millimetre out of true in the first course multiplies up the height of the wall.

  2. 2

    Damp the block, do not soak it

    The surface should be damp so it does not draw water out of the mortar. A soaked block does the opposite and destroys adhesion.

  3. 3

    Fill the bed joint completely

    A partial joint lowers strength and opens a path for sound and heat. With tongue-and-groove, the perpend joint disappears.

  4. 4

    No opening without a lintel

    Even small openings need a lintel. A ceramic lintel also keeps the thermal continuity of the facade.

  5. 5

    A metre and a half a day, at most

    Going higher in one go compresses the fresh mortar in the courses below and throws the wall out of plumb.

Used in

Projects built with this product

Related

Related products

Popular KW-15
عایق حرارتی
55
عایق صوتی
72
مقاومت سازه‌ای
58

بلوک دیواری

بلوک سفالی ۱۵

25 × 15 × 20 cm

دیوار جداکننده بین واحدها

λ
0.29 W/m·K
Weight
7.8 kg
Strength
5 MPa
KW-15-2
عایق حرارتی
55
عایق صوتی
72
مقاومت سازه‌ای
58

بلوک دیواری

بلوک سفالی ۱۵ (کپی)

25 × 15 × 20 cm

دیوار جداکننده بین واحدها

λ
0.29 W/m·K
Weight
7.8 kg
Strength
5 MPa
Popular KW-25
عایق حرارتی
86
عایق صوتی
88
مقاومت سازه‌ای
80

بلوک دیواری

بلوک سفالی ۲۵

40 × 25 × 25 cm

پوسته حرارتی بدون عایق افزوده

λ
0.21 W/m·K
Weight
14.8 kg
Strength
7.5 MPa