Skip to main content

Drag to rotate — or use the arrow keys

Click the points on the section

The highlighted points on the section explain the block’s internal structure.

بلوک تیغه‌ای

بلوک تیغه‌ای ۱۳

KP-13-2

40 × 18.5 × 13 cm

سیزده سانتی‌متر ضخامت، تعادل میان وزن، صداگیری و سرعت اجرا؛ انتخاب متداول برای دیوارهای داخلی و جداکننده‌ی واحدها.

  • Thermal

    λ = 0.31

    Thermal insulation

  • Acoustic

    42 dB

    Sound insulation

  • Fire

    135 min

    Fire resistance

Specifications

Technical specifications for بلوک تیغه‌ای ۱۳
Property Value
Nominal dimensions 40 × 18.5 × 13 cm
Wall thickness 13 cm
Weight each 6 kg
Compressive strength 4.5 MPa
Thermal conductivity (λ) 0.31 W/m·K
Thermal resistance (R) 0.419 m²·K/W
Water absorption 14.8 %
Sound reduction 42 dB
Fire resistance 135 min
Void ratio 55 %
Units per m² 20 pcs
Units per pallet 150 pcs
Mortar used 16 litres/m²
  • استاندارد ملی ایران ۷
  • مبحث ۸ مقررات ملی ساختمان

Why this product?

سیزده سانتی‌متر ضخامت، تعادل میان وزن، صداگیری و سرعت اجرا؛ انتخاب متداول برای دیوارهای داخلی و جداکننده‌ی واحدها.

عایق حرارتی
50
عایق صوتی
66
مقاومت سازه‌ای
52

Features

  • سرعت اجرای بالا با ابعاد ماژولار
  • کاهش صوت ۴۲ دسی‌بل
  • سازگار با گچ و خاک و گچ‌کاری ماشینی

Applications

  • دیوار داخلی واحدهای مسکونی
  • دیوار راه‌پله
  • جداکننده فضاهای اداری

Installation

How it is laid

The five points that matter most to how the finished wall performs.

Full installation guide
  1. 1

    Level the bed

    The first course goes on a perfectly level mortar bed. Every millimetre out of true in the first course multiplies up the height of the wall.

  2. 2

    Damp the block, do not soak it

    The surface should be damp so it does not draw water out of the mortar. A soaked block does the opposite and destroys adhesion.

  3. 3

    Fill the bed joint completely

    A partial joint lowers strength and opens a path for sound and heat. With tongue-and-groove, the perpend joint disappears.

  4. 4

    No opening without a lintel

    Even small openings need a lintel. A ceramic lintel also keeps the thermal continuity of the facade.

  5. 5

    A metre and a half a day, at most

    Going higher in one go compresses the fresh mortar in the courses below and throws the wall out of plumb.

Related

Related products

Popular KP-08
عایق حرارتی
40
عایق صوتی
54
مقاومت سازه‌ای
42

بلوک تیغه‌ای

بلوک تیغه‌ای ۸

20 × 18.5 × 8 cm

سبک‌ترین جداکننده داخلی

λ
0.355 W/m·K
Weight
3.6 kg
Strength
3.5 MPa
Popular KP-08-2
عایق حرارتی
40
عایق صوتی
54
مقاومت سازه‌ای
42

بلوک تیغه‌ای

بلوک تیغه‌ای ۸

40 × 18.5 × 8 cm

سبک‌ترین جداکننده داخلی

λ
0.355 W/m·K
Weight
3.6 kg
Strength
3.5 MPa
Popular KP-13
عایق حرارتی
50
عایق صوتی
66
مقاومت سازه‌ای
52

بلوک تیغه‌ای

بلوک تیغه‌ای ۱۳

20 × 18.5 × 13 cm

پرکاربردترین بلوک داخلی

λ
0.31 W/m·K
Weight
6 kg
Strength
4.5 MPa