Skip to main content

Drag to rotate — or use the arrow keys

Click the points on the section

The highlighted points on the section explain the block’s internal structure.

بلوک حرارتی

بلوک حرارتی ۲۰ پلاس

KT-20P

40 × 20 × 25 cm

آرایش حفره‌ی زیگزاگی مسیر انتقال حرارت را طولانی می‌کند؛ عملکرد حرارتی نزدیک به بلوک ۲۵ بدون از دست دادن فضای مفید.

  • Thermal

    λ = 0.19

    Thermal insulation

  • Acoustic

    47 dB

    Sound insulation

  • Fire

    180 min

    Fire resistance

Specifications

Technical specifications for بلوک حرارتی ۲۰ پلاس
Property Value
Nominal dimensions 40 × 20 × 25 cm
Wall thickness 20 cm
Weight each 10.4 kg
Compressive strength 6 MPa
Thermal conductivity (λ) 0.19 W/m·K
Thermal resistance (R) 1.053 m²·K/W
Water absorption 13.2 %
Sound reduction 47 dB
Fire resistance 180 min
Void ratio 63 %
Units per m² 10 pcs
Units per pallet 90 pcs
Mortar used 20 litres/m²
  • استاندارد ملی ایران ۷
  • مبحث ۱۹ مقررات ملی ساختمان

Why this product?

آرایش حفره‌ی زیگزاگی مسیر انتقال حرارت را طولانی می‌کند؛ عملکرد حرارتی نزدیک به بلوک ۲۵ بدون از دست دادن فضای مفید.

عایق حرارتی
90
عایق صوتی
76
مقاومت سازه‌ای
68

Features

  • مسیر زیگزاگی انتقال حرارت
  • وزن کمتر از بلوک ۲۵ با λ نزدیک به آن
  • حفظ فضای مفید داخلی

Applications

  • بازسازی نما با محدودیت ضخامت
  • دیوار خارجی برج مسکونی
  • پروژه‌های بهینه‌سازی انرژی

Installation

How it is laid

The five points that matter most to how the finished wall performs.

Full installation guide
  1. 1

    Level the bed

    The first course goes on a perfectly level mortar bed. Every millimetre out of true in the first course multiplies up the height of the wall.

  2. 2

    Damp the block, do not soak it

    The surface should be damp so it does not draw water out of the mortar. A soaked block does the opposite and destroys adhesion.

  3. 3

    Fill the bed joint completely

    A partial joint lowers strength and opens a path for sound and heat. With tongue-and-groove, the perpend joint disappears.

  4. 4

    No opening without a lintel

    Even small openings need a lintel. A ceramic lintel also keeps the thermal continuity of the facade.

  5. 5

    A metre and a half a day, at most

    Going higher in one go compresses the fresh mortar in the courses below and throws the wall out of plumb.

Used in

Projects built with this product

Related

Related products

Popular KP-08
عایق حرارتی
40
عایق صوتی
54
مقاومت سازه‌ای
42

بلوک تیغه‌ای

بلوک تیغه‌ای ۸

20 × 18.5 × 8 cm

سبک‌ترین جداکننده داخلی

λ
0.355 W/m·K
Weight
3.6 kg
Strength
3.5 MPa
Popular KP-08-2
عایق حرارتی
40
عایق صوتی
54
مقاومت سازه‌ای
42

بلوک تیغه‌ای

بلوک تیغه‌ای ۸

40 × 18.5 × 8 cm

سبک‌ترین جداکننده داخلی

λ
0.355 W/m·K
Weight
3.6 kg
Strength
3.5 MPa
Popular KP-13
عایق حرارتی
50
عایق صوتی
66
مقاومت سازه‌ای
52

بلوک تیغه‌ای

بلوک تیغه‌ای ۱۳

20 × 18.5 × 13 cm

پرکاربردترین بلوک داخلی

λ
0.31 W/m·K
Weight
6 kg
Strength